Cla-val X144 Technical Manual Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Zařízení Cla-val X144 Technical Manual. Cla-Val X144 Technical Manual User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Operation

X144 e-FlowMeterInstallationMaintenance Operation

Strany 2 - Proven Technology from

Section 2: Installation of the X144 e-FlowMeter (continued) 2.3 - Mounting the X144 e-FlowMeterMount the X144 e-FlowMeter in a proper orientation as s

Strany 3 - Operation and Maintenance

Section 2: Installation of the X144 e-FlowMeter (continued)2.4 - Step-by-Step Instructions: Mechanical InstallationCAUTION: BEFORE removing pipe plug,

Strany 4 - 800.942.6326

Section 2: Installation of the X144 e-FlowMeter (continued)2.4 - Step-by-Step Instructions Mechanical Installation6) Screw threaded insert into the i

Strany 5 - 1.1 - Theory of Operation

Section 2: Installation of the X144 e-FlowMeter (continued)2.4 - Step-by-Step Instructions Mechanical Installation8) Once the measurement cylinder ro

Strany 6

Section 2: Installation of the X144 e-FlowMeter (continued)2.4 - Step-by-Step Instructions Mechanical Installation10) Ensure that the e-FlowMeter is

Strany 7 - 1.3 – Non-Supplied Parts List

Section 2: Installation of the X144 e-FlowMeter (continued)2.5 - Step-by-Step Instructions: Electrical Installation for General ApplicationsFigure 2-1

Strany 8

Section 2: Installation of the X144 e-FlowMeter (continued)13Digital PulseorTransistor (NPN)PulseX144e-Flow Metergreenblueredgreypinkyellowwhitebrown1

Strany 9

Section 2: Installation of the X144 e-FlowMeter (continued)2.6 - Wiring Installation14redyellowpinkbluegrey- 0Vblackred- 0V12/ 24 VDCX144 e-Flow Meter

Strany 10

SECTION 3: X144 e-FlowMeter Operation 3.1 – Starting Operation Follow this procedure when starting the installation for the first time or after shutti

Strany 11 - Figure 2-5

SECTION 3: X144 e-FlowMeter Operation3.2 – Stopping Operation/Removal of X144 e-FlowMeter1) Close the shut-off valves to stop the flow of water, ble

Strany 12 - Figure 2-7

A view inside the X144 e-FlowMeterPlug-and-Play Metering: Cla-Val X144 e-FlowMeterProven Technology fromthe Industry LeaderLaboratory Tested • Field

Strany 13 - Figure 2-8

SECTION 3: X144 e-FlowMeter Operation3.2 – Stopping Operation / Removal of X144 e-FlowMeterd) Slide Insertion Tool straight out, then rotate 180 degre

Strany 14 - Log onto www.cla-val.com

SECTION 4: Maintenance and Repair 4.1 – Routine Maintenance CAUTION: Always disconnect the power supply, isolate and depressurize the system before pe

Strany 15 - 2 3 4 5 6

SECTION 5: SpecificationsTable 2: Electrical SpecificationsEnclosure Stainless Steel (standard)Output Signal Options:• Digital Pulse, proportionalto f

Strany 16 - Damage will occur

SECTION 5: Specifications (continued)Dimensional DataFigure 5-1: X144 e-FlowMeter Table 4: X144 e-FlowMeter Dimensions20X144 Sizes1 2 3 4Full Port Va

Strany 17 - Figure 2-16:

SECTION 5: Specifications (continued)3.43” 0.04”6.5-inches4.76” 0.04”Insertion Tools: Overall Length •T1 = 6-1/2”• T2 = 14-1/2”Figure 5-2: X144 Inser

Strany 18 - (100-49 Body)

Table 6: X144 e-FlowMeter Operational Flow Ranges22Table 7: X144 e-FlowMeter Analog Range (4-20mA Scaling): Factory SettingsIf required, the factory s

Strany 19 - Figure 3-3

X144 e-FlowMeterQuick Start Installation & Removal Instructions X144 e-FlowMeter Included Hardwarepatent pendingCompletee-FlowMeter AssemblyParts

Strany 20 - Figure 3-6

24X144 e-FlowMeterQuick Start Installation & Removal Instructions 7651098Step 5: Insert straightened Swivel Insert/MeasurementCylinder Assembly in

Strany 21

25X144 e-FlowMeterQuick Start Installation & Removal Instructions Digital PulseorTransistor (NPN)PulseX144e-Flow Metergreenblueredgreypinkyellowwh

Strany 22 - SECTION 5: Specifications

26X144 e-FlowMeterQuick Start Installation & Removal Instructions Before3Step 3: • Remove the e-FlowMeter Sensor/Head Assembly bypulling straight

Strany 23 - Figure 5-1: X144 e-FlowMeter

X144 e-FlowMeter Installation,Operation and MaintenanceTable of ContentsTopic

Strany 24

www.cla-val.com • 800-942-6326 EASTERN REGION6911 Richmond Highway, Suite 444Alexandria, VA 22306Phone: (800) 451-3030Fax: (703) 721-1927E-mail:

Strany 25

INTRODUCTION: X144 e-FlowMeter Installation, Maintenance and Operation The X144 is an insertion flow meter designed to provide flow information from i

Strany 26

SECTION 1: System Components and How They Work 1.1 - Theory of Operation The X144 e-FlowMeter is an insertion vortex flowmeter based on a phenomenon w

Strany 27

3Figure 1-4: e-FlowMeterX144 e-FlowMeter Parts1) IP68 Submersible Electronics Housing 2) Knurled Lock 3) Centering Pin4) O-Ring 5) Shaft 6) Sensor1265

Strany 28

SECTION 1: System Components and How They Work (continued) 1.3 – Non-Supplied Parts ListThe following parts are necessary for installation and operati

Strany 29

Section 2: Installation of the X144 e-FlowMeter 2.1 - Installation Locations:For optimum performance, it is recommended that the valve in which the X1

Strany 30 - N-X144 IOM (R-03/2013)

Section 2: Installation of the X144 e-FlowMeter (continued)2.2 - Materials Required for Installation Insertion tool • Tool allows the proper installa

Komentáře k této Příručce